Smart Parts Epiphany Manual - English

Text from this manual

EPIPHANY Operation and adjustment instructions

Q UIC K START 01 BATTERY

PLEASE READ CAREFULLY

02 BARREL BLOCKER Screw the included barrel into the Epiphany. Put the supplied barrel blocker over the end of the barrel, securing its cord as far back on the Epiphany body as possible, and cinching it tight.

Using a 5/64-inch Allen wrench, remove the two screws from the left side of the rubber grip and lift the panel open. Attach a fresh 9-volt alkaline battery to the battery clip. Position the battery in the grip frame, tucking the battery wires into the space above the battery. Close the grip and reinstall the screws.

04 LOADER

03 FILL TANK

05 TURN ON AIR Insert your loader into the feedneck and make sure it is secure. Due to the high rates of fire that the Epiphany can achieve, we recommend the use of a modern high-performance loader. Be sure the loader fits securely and is twist-fit in place with a clockwise motion (see the Hopper section.)

Have your compressed air (HPA) or CO2 tank filled by a person who is properly trained to do so. If using an HPA system with an on/off valve, such as the Max-Flo or Max-Flo Micro, make sure it is in the OFF position.

06 TURN ON EPIPHANY Gently gas up the marker by slowly turning on the air system or ASA’s on/off valve, or slowly screwing the CO2 or compressed air system into the ASA. A gentle rise in pressure is important, as a sudden blast may reduce the service life of the Epiphany’s internals.

POWER BUTTON

Turn on the marker by holding the power button down for approximately 2 seconds. The marker will turn on with Vision mode activated. The light will blink slowly if there is no paintball in the breech, or rapidly if there is. To de-activate Vision mode, press the power button briefly and it will blink in a double-tap sequence. Press it briefly again to re-activate Vision mode. Press and hold the power button for approximately 2 seconds to turn the Epiphany off.

07 ADJUST VELOCITY Fill the loader with paint and turn it on. While wearing ASTM compliant paintball goggles, in an area where all bystanders are protected, remove the barrel blocker and fire over a chronograph to measure the velocity. Using a 5/8-inch open-end wrench or adjustable wrench on the flats at the bottom of the vertical regulator, turn clockwise to increase velocity/pressure, and counter-clockwise to decrease. Take three or four shots after every adjustment to allow the gas pressure inside the Epiphany to stabilize. Adjust until the marker is firing consistently within the limits for the field where you are playing (for safety reasons, never adjust the Epiphany to fire at greater than 300 feet per second.) As you adjust, check the Epiphany’s pressure gauge to be certain you stay below the Epiphany’s operating limit of 280 psi. Depending on what modes of fire are allowed at the field where you are playing (semi-automatic, rebound, etc.) you may need to adjust the Epiphany’s firing mode. See the Electronic Adjustment section for more information. Shoot out the competition, hang the flag and win the game.

www.smartparts.com

TABLE OF CONTE N T S Quick Start

– THE EPIPHANY IS NOT A TOY

Getting Familiar

– MISUSE OF THE EPIPHANY MAY RESULT IN SERIOUS INJURY OR DEATH.

Barrel Blocker/Hopper

Gas System Mounting

– EYE PROTECTION SPECIFICALLY DESIGNED FOR PAINTBALL USE MUST BE IN COMPLIANCE WITH ASTM SPECIFICATION F1776 AND MUST BE USED BY THE USER AND ANYONE WITHIN RANGE OF THE EPIPHANY

Paint/Velocity

Vision/Degassing

– THOROUGHLY READ THE EPIPHANY OPERATION AND INSTRUCTION MANUAL BEFORE OPERATING.

Electronic Adjustment

– TREAT EVERY PAINTBALL MARKER AS IF IT WERE LOADED.

ROF Delay/Fire Modes

– NEVER LOOK DOWN THE BARREL OF A PAINTBALL MARKER.

Trigger

[ DISASSEMBLY/REASSEMBLY ]

– SMART PARTS RECOMMENDS THAT THE EPIPHANY ONLY BE SOLD TO PERSONS 18 AND OLDER.

– KEEP YOUR FINGER OFF THE TRIGGER UNTIL READY TO SHOOT.

EPIPHANY Parts

– NEVER POINT THE EPIPHANY AT ANYTHING YOU DON’T WISH TO SHOOT.

Disassembly

– KEEP THE EPIPHANY ON SAFE (POWER OFF) UNTIL READY TO SHOOT. (SEE QUICK START)

Reassembly

Epiphany Volume Inserts

– KEEP THE BARREL BLOCKING DEVICE ON THE EPIPHANY’S MUZZLE WHEN NOT SHOOTING. (SEE BARREL BLOCKER SECTION).

Solenoid

Regulator

Ball Detents

Troubleshooting

Warranty/Tech Support

CPS Table

While every effort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for errors or omissions. Smart Parts, Inc. reserves the right to change the specifications of the Epiphany at any time without prior notice. The latest version of this manual may be downloaded free of charge at www.SmartParts.com.

– ALWAYS REMOVE PAINTBALLS AND DEGAS THE EPIPHANY BEFORE DISASSEMBLY. (SEE DEGASSING SECTION.) – STORE AND TRANSPORT THE EPIPHANY UNLOADED AND DEGASSED IN A SECURE PLACE. – FOLLOW ALL MANUFACTURER’S WARNINGS AND INSTRUCTIONS FOR PROPELLANT SOURCE HANDLING, STORAGE, AND FILLING. – DO NOT SHOOT FRAGILE OBJECTS SUCH AS WINDOWS. – ALWAYS MEASURE THE VELOCITY OF PAINTBALLS FIRED BY THE EPIPHANY BEFORE USE, AND NEVER ADJUST TO FIRE ABOVE 300FPS (91.44 M/S)

Extracted from the PDF. Read the full manual above, or download it.

Brand
Product Name
Epiphany Manual
Product Type
Language
English
File Size
2.4 MB
File Type
PDF